Engineering Guides · Module 03
Sizing DC-DC converters and power distribution
A converter draws more current from the battery than it gives to the load, and it draws the most when the battery is lowest.
Assumptions: Numbers in the examples are illustrative and the code is executed by the site’s tests. Type and characteristic summaries are general engineering knowledge; always confirm values on the datasheet of the part you use.
1. Engineering problem
Each subsystem needs its own voltage (24 V motors, 12 V computer, 5 V sensors). A converter that is undersized, a fuse that is too large and a thin cable each cause a different failure: brownout, fire risk or a voltage drop that resets a device.
2. When is this needed?
- After the power budget lists consumers and voltages.
- When adding a sensor with a different supply voltage.
- When a device resets at high motor load.
3. Selection and design decisions
Choose between buck (step-down), boost, buck-boost and isolated converters by the input and output voltage ranges. Use isolated converters when the noise or safety design needs galvanic isolation.
| Check | How |
|---|---|
| Output power | Sum of consumers at peak, plus margin |
| Input current | Pout ÷ efficiency ÷ Vin; the highest value is at the lowest Vin |
| Loss | Pin − Pout, which must be removed as heat |
| Fuse | At least 1.25 × worst-case continuous current (a common rule; check the converter and wire ratings) and below the wire rating |
| Cable drop | I × R of the run; keep it small against the receiver’s margin |
| Separate rails | Noisy loads (motors) and sensitive loads (sensors) on separate converters or filtered branches |
4. Advantages and disadvantages
- One converter for everything is simple and couples noise; separate converters isolate faults and noise.
- High efficiency usually costs more; the loss shows up as heat.
- Headroom: running a converter near its rating shortens life and increases heat.
5. Requirements and constraints
- Converter input range covers the pack from empty to fully charged.
- Rated output current ≥ peak load with margin.
- Fuse protects the wire and converter, not the load alone.
- Datasheet efficiency curve is read at the actual load, not at the best point.
6. Architecture
battery ─▶ main fuse ─▶ distribution ─┬▶ motor drivers (24 V)
├▶ DC-DC 12 V ─▶ computer
└▶ DC-DC 5 V ─▶ sensors, MCU7. Implementation
- Sum the load power per rail at peak.
- Divide by the datasheet efficiency at that load and by the lowest pack voltage to get the worst-case input current.
- Choose the fuse and wire gauge for that current.
- Compute the converter loss and check the thermal design.
- Compute the cable drop for the longest run.
def dcdc(p_out, eff, v_in_min, v_in_max):
p_in = p_out / eff
return {"p_in W": round(p_in, 1), "I at vmin A": round(p_in / v_in_min, 2), "I at vmax A": round(p_in / v_in_max, 2), "loss W": round(p_in - p_out, 1)}
r = dcdc(60, 0.90, 20.0, 29.4)
print(r)
print("fuse (1.25 x worst-case current):", round(1.25 * r["I at vmin A"], 1), "A minimum rating")
drop = 8.0 * 0.020
print(f"cable drop: {drop:.2f} V at 8 A over 20 mOhm")Printed (checked by the site’s tests):
{'p_in W': 66.7, 'I at vmin A': 3.33, 'I at vmax A': 2.27, 'loss W': 6.7}
fuse (1.25 x worst-case current): 4.2 A minimum rating
cable drop: 0.16 V at 8 A over 20 mOhmReading it: a 60 W load on a 90 % efficient converter draws 66.7 W; at the lowest pack voltage (20 V) that is 3.33 A, at the highest (29.4 V) 2.27 A. A 4.2 A fuse or larger covers the 3.33 A worst case with a 25 % margin, and 6.7 W has to leave as heat. A cable resistance of 20 mΩ carrying 8 A drops 0.16 V. Efficiency, voltages and resistance are illustrative.
8. Real examples
- AMR: 24 V pack to the motor drivers through one fuse, a 12 V converter for the computer and a separate 5 V converter for the sensors.
9. Failure scenarios
- The fuse was sized on the average current and blew on start-up.
- A converter was run outside its input range at full charge.
- A thin power cable to a sensor dropped enough voltage to reset it at motor start.
10. Troubleshooting
- If a device resets, measure its supply with an oscilloscope during the event.
- If a converter is too hot, compare the loss with the thermal design.
- If a fuse blows, log the current and check for inrush.
11. Validation
- The example prints the values above (executed by the site tests).
- Measured voltage at each consumer stays inside its input range under the worst-case load step.
- Converter temperature stabilises with margin.
12. Engineering checklist
13. Further references
- Datasheets of the converters used (input range, efficiency curve, output current, thermal derating) and of the fuses and wire.